Legionella
Enable:
Time:
NO
Mon:
Tue:
Wed:
Thu:
Fri:
Sat:
Sun:
XXXXX XXXXX
58
Emergency:
Support:
58
3.14.
POOL Menu
User Menu
/9
DHW/Legionella prot
Pool
e-Manager
Pool
Enable:
Remote control: OFF
SetT:
DTstart:
Pool
Winter program
minutes per hour:
5

HTR system
Winter:

Summer:
XXXXX XXXXX
58
Emergency:
Support:
58
Legionella protection program
3:
Used to set up a weekly program for legionella protection.
The legionella protection program is deactivated automatically if 5 hours have elapsed
without reaching the final temperature set up by the technical service.
Note: Legionella protection programs should be carried out at night, or when there is no
DHW consumption.
Auxiliary DHW
This is used to enable the auxiliary DHW system in both EMERGENCY and SUPPORT
mode.
Note: In EMERGENCY mode, the auxiliary system is activated automatically if there are
any active alarms that prevent compressor start-up.
In SUPPORT mode, the auxiliary system is activated automatically for normal DHW
production, as programmed by the technical service.
Pool
Used to enable the POOL mode.
Used to set the setpoint temperature and the pool start-up temperature differential
5

(available depending on the unit options).
The
icon indicates that there is a time schedule activated in the POOL mode.
Percentage minutes/hour
Used to adjust the percentage of minutes/hours that the heat pump dedicates to POOL

mode when there are simultaneous heating and pool requests with the WINTER
programme (available depending on unit options).
HTR system
Used to enable the POOL production through the HTR independently in the winter
and/or summer program.
Auxiliary pool
Used to enable the auxiliary POOL system in both EMERGENCY and SUPPORT mode.
Note: In EMERGENCY mode, the auxiliary system is activated automatically if there are any
active alarms that prevent compressor start-up.
In SUPPORT mode, the auxiliary system is activated automatically for normal POOL
production, as programmed by the technical service.
51
User manual