Installation And Operation - Quick Tools Quts8 Bedienungsanleitung

Lötstation 150w
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
2.4.2. Buttons
In the main menu, 3 memory locations with individually set
parameters can be selected directly.
In the main menu, press buttons 2 and 3 for at least 3s opens
1
the settings menu.
2
In the main menu, press buttons 1 and 3 for at least 3s opens
3
the calibration menu.
In the settings menu, key 1 moves the cursor down, key 2
saves, button 3 switches back to the main menu.
In the main menu, the temperature is increased.
+
In the settings menu, the cursor is moved up.
In the main menu, the temperature is lowered.
-
In the settings menu, the cursor is moved down.
2.5.

Installation and Operation

CAUTION: Before switching on, check that the operating voltage
corresponds to the voltage specified on the rating plate!
Make sure that the station is always switched off when plugging or
unplugging the soldering iron connection cable. Failure to do so may
result in damage.
Soldering iron holder
2.5.1
In the storage stand there is a viscose sponge and brass cleaning wool.
NOTE: Make sure that the sponge is not used dry.
1.
Unpack the sponge
2.
Pour some water into the tray
3.
Insert sponge