Herunterladen Diese Seite drucken

Atlas Copco Power Focus 4002 Compact Original-Produktanweisungen Seite 8

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
Safety Information
Decommissioning
Recycling instruction
When a product has served its purpose it has to be
recycled properly. Dismantle the product and recy-
cle the components in accordance with local legis-
lation.
Batteries shall be taken care of by your national
battery recovery organization.
Technical data
Technical data
Technical data
Weight
12 kg
Power
Power Focus operates on a single-phase 110 or
230 VAC line voltage.
Power Focus has a function for sensing the line
voltage automatically. This means that the Power
Focus automatically switches to the voltage you
connect to.
Line voltage
90-120 VAC
180-240 VAC
Frequency
50-60 Hz
Ambient temperature
5-40 °C (41-104 °F)
Normal environmental conditions
This standard applies to equipment designed to be
safe at least under the following conditions:
• Indoor use
• Altitude up to 2 000 m
• Maximum relative humidity 80% for tempera-
tures up to 31°C decreasing linearly to 50% rel-
ative humidity at 40°C
• Transient over voltages typically present on the
mains supply
8
© Atlas Copco Industrial Technique AB - 9836 4581 00
Power Focus 4002 Compact
Power consumption
Power consumption depends on the speed and
torque of the tool. High speed and torque increase
power consumption.
Tool
Standby [W]
SL
20
Mains fuse
Recommended mains fuses (power outlet):
Mains voltage
Tool
[V]
SL
110
230
If you are running Power Focus as a standalone
unit and trigger the tools manually (random) it is
normally possible to connect up to three Power Fo-
cus units to one power drop. If you are synchronis-
ing the spindles you will need one drop for each
Power Focus unit.
Wiring
All connections except for the USB plug are lo-
cated on the rear of the unit. See the dimensions
drawing for location of the USB plug. If it is nec-
essary to change the plug on the mains cable, use
the following wiring guide:
Color
Brown or black
Blue
Green and yellow
Warning! The power cable is the main disconnect-
ing device. If you open a Power Focus unit first
pull out the power cable to make sure that the unit
is free from electric power.
Free running
[W]
150
Fuse [A]
15
10
Input
Live
Neutral
Protective ground