6.
Constantly move the power tool over the surface.
Note: lf you want to avoid irregular grinding results,
do not keep the power tool at one spot for too long.
7.
Lift the grinding plate (9) from the surface to be
processed before switching off the power tool.
8.
Do not put aside the power tool until the insertion
tool has come to a complete halt.
After use
1.
Switch off the power tool as described, discon-
nect it from the power supply and Iet it cool down.
2.
Clean and maintain the power tool as described
below, and store it carefully.
9.
Cleaning, maintenance and repair
m WARNING!
Unplug the power tool before starting to work on
it (e.g. transport, installation, retrofitting, cleaning
and maintenance)!
Cleaning
a)
Keep protective devices, ventilation openings and
motor housings free from dust and dirt as far as
possible.
b)
Wipe the power tool with a clean cloth or remove
dust and dirt with compressed air at low pressure
(max. 3 bar).
c)
Clean the power tool immediately after each use.
d)
Do not use any detergents or solvents as they may
affect the plastic parts of the power tool. Make
sure to avoid any water ingress into the tool.
Replacing the power supply line
lf the power supply line of this power tool is damaged,
it must be replaced by the manufacturer or the cus-
tomer service or any equally qualified person in order
to avoid risks.
Maintenance
Check the power tool and accessory parts (e.g. inser-
tion tools) for wear and damage before and after each
operation. lf necessary, replace worn out or damaged
parts with new parts and make sure to comply with the
operating instructions.
Observe any technical requirements.
Grinding plate, brush edge
Have a qualified specialist replace damaged or worn
out grinding plates (9) and brush edges (10) with new
ones of the same type.
28 | GB
Service information
Please note that the following parts of this product are
subject to normal or natural wear and that the following
parts are therefore also required for use as consum-
ables.
Wear parts*: carbon brushes, grinding wheel, brush
head, sand paper
* not necessarily included in the scope of delivery!
Spare parts and accessories can be obtained from our
service centre. To do this, scan the QR code on the
cover page.
10. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
Damaged electrical connection cable.
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must
not be used and are life-threatening due to the in-
sulation damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F".
The printing of the type designation on the connection
cable is mandatory.