Technical specifications
7 Technical specifications
■ Compact R
Performance data
Electrical data
Configuration
■ Compact K
Performance data
Electrical data
Configuration
■ Compact L plus
Performance data
Electrical data
Configuration
■ General data
Performance data
Electrical data
Mechanical data
2024/11
Operating instructions Compact R | Compact K | Compact L plus
Flow rate:
Back pressure:
Operating voltage:
Setting of operating
mode:
Setting of speed:
Setting of runtime:
Flow rate:
Back pressure:
Operating voltage:
Setting of operating
mode:
Setting of speed:
Setting of runtime:
Flow rate:
Back pressure:
Operating voltage:
Setting of switching point:
Conductivity control:
Duty cycle:
Suction height:
Power consumption:
Protection class:
Dimensions:
Weight:
Tube connection:
2 ... 75 ml/min
max. 0.5 bar
230 V AC 50/60 Hz (Art. no.: 98273)
24 V AC, 50/60 Hz (Art. no.: 98279)
12 to 24 V DC (Art. no.: 98289)
With potentiometer (speed or runtime)
With potentiometer (2.5 ... 75 ml/min)
With potentiometer (1 ... 60 sec, 1 second ≙ 1 ml)
1.3 ... 10 ml/min
max. 2 bar
230 V AC 50/60 Hz (Art. no.: 99036)
24 V AC, 50/60 Hz (Art. no.: 99037)
12 to 24 V DC (Art. no.: 99039)
With potentiometer (speed or runtime)
With potentiometer (1.3 ... 10 ml/min)
With potentiometer (1 ... 60 sec, 1 second ≙ 0.3 ml)
75 ml/min
max. 0.5 bar
230 V AC 50/60 Hz (Art. no.: 10090)
24 V AC, 50/60 Hz (Art. no.: 10093)
With potentiometer
With conductive electrode (0.5 ... 1.5 mS)
30%
1.8 m
5.5 VA
IP 65
65 x 135 x 82 mm
0.6 kg
5x1.5 mm (5/8 mm), alternatively 6x2 (6/10)
EN
27 / 56