You could also calculate the values in the table below yourself if necessary:
Example:
32: 20°dH = 1600 litres of soft water
48: 20°dH = 2400 litres of soft water
72: 10°dH = 7200 litres of soft water
As the systems regenerate at night but exhaustion can occur before this, we recommend a safety factor
of 0.95 up to 18 °dH and 0.90 from a raw water hardness of 19°dH and higher.
Example:
32: 20°dH = 1600 litres of soft water x 0.90 = 1440 litres of soft water
72: 10°dH = 7200 litres of soft water x 0.95 = 6840 litres of soft water
Water hard-
R2D2-32
ness:
10
3.20
11
2.91
12
2.67
13
2.46
14
2.29
15
2.13
16
2.00
17
1.88
18
1.78
19
1.68
20
1.60
21
1.52
22
1.45
23
1.39
24
1.33
25
1.28
26
1.23
27
1.19
28
1.14
29
1.10
30
1.07
31
1.03
32
1.00
33
0.97
34
0.94
35
0.91
Model
R2D2-48
R2D2-72
4.80
7.20
4.36
6.55
4.00
6.00
3.69
5.54
3.43
5.14
3.20
4.80
3.00
4.50
2.82
4.24
2.67
4.00
2.53
3.79
2.40
3.60
2.29
3.43
2.18
3.27
2.09
3.13
2.00
3.00
1.92
2.88
1.85
2.77
1.78
2.67
1.71
2.57
1.66
2.48
1.60
2.40
1.55
2.32
1.50
2.25
1.45
2.18
1.41
2.12
1.37
2.06