Time of day
4
5
Regen.time.
6
Regen.days
7
Capacity
Volume delayed
Volume not
take into account
2:00
7
R2D2-32 = 1.45 to.
R2D2-48 = 2.10 to.
R2D2-72 = 3.20 to.
In this mode, the system regenerates af-
ter reaching a fixed programmed volume
of water. Once the set volume has been
reached, regeneration takes place at a set
time (delayed).
Abbreviation in the display: (Volume de-
layed)
In this mode, the system regenerates af-
ter reaching a fixed programmed volume
of water. Once the set volume has been
reached, regeneration takes place at a
specific time (delayed). In addition, a
forced regeneration is triggered after a
preset number of days, regardless of the
volume used. This prevents the system
from becoming contaminated when no
water is being used (e.g. during holidays).
Abbreviation in the display: Volume not
taken into account
Set the time here.
Enter the time here at which the
system should regenerate. We recom-
mend 2:00 a.m., as water is rarely used at
this time.
Enter the number of days here,
after which the system should regenerate
(only in the mode "Volume control imme-
diate" and "Volume not considered").
The softening capacity is preset
here. The capacity is calculated from the
existing water hardness and the amount
of softener resin, as well as the desired
blending at the control valve.