For Magellan SL™ scanner/scale models, the Scale
Zero switch is used to start the scale re-zero process.
This operation may be performed by checkers and
other store personnel.
To initiate the scale zero process:
1. Ensure that the scanner/scale is powered-up
and is at operating temperature.
2. Remove everything from the weighing
surface of the scanner/scale.
3. Press and release the Scale Zero switch.
4. The Zero LED will light and the display
will show 0.00 lb (0.000 kg).
At this point, the scanner/scale should return to
normal operation. If, for some reason, the scale
fails to zero, it could be because of a buildup of
debris preventing the scale from functioning
properly. Follow the instructions given in the
previous section titled: Cleaning the Debris
Chutes to remedy this problem.
After cleaning the debris chutes, if the scale still
refuses to reset its zero point, it's likely that the
scale requires recalibration or other qualified
service. Call your technical support personnel
and report the problem. Note that calibration
must be performed in accordance with the legal
requirements of your local Weights and Mea-
sures authorities.
5. This completes the scale zero procedure.
72-50501-01 Rev. A
M
OUTINE
AINTENANCE
CALE
CONTINUED