Proline Prowirl F 200
Endress+Hauser
Zündschutzart Ex ic
Bestellmerkmal "Ausgang"
Option A
Option B
Option C
Option D
Option E
Ausgangstyp
4-20mA HART
4-20mA HART
Impuls-/Frequenz-/Schaltausgang
4-20mA HART
4-20mA analog
4-20mA HART
Impuls-/Frequenz-/Schaltausgang
4...20 mA Stromeingang
FOUNDATION Fieldbus
Impuls-/Frequenz-/Schaltausgang
Eigensichere Werte
U
= DC 35 V
i
I
= n.a.
i
P
= 1 W
i
L
= 0 μH
i
C
= 5 nF
i
U
= DC 35 V
i
I
= n.a.
i
P
= 1 W
i
L
= 0 μH
i
C
= 5 nF
i
U
= DC 35 V
i
I
= n.a.
i
P
= 1 W
i
L
= 0 μH
i
C
= 6 nF
i
U
= DC 30 V
i
I
= n.a.
i
P
= 1 W
i
L
= 0 μH
i
C
= 30 nF
i
U
= DC 35 V
i
I
= n.a.
i
P
= 1 W
i
L
= 0 μH
i
C
= 5 nF
i
U
= DC 35 V
i
I
= n.a.
i
P
= 1 W
i
L
= 0 μH
i
C
= 6 nF
i
U
= DC 35 V
i
I
= n.a.
i
P
= 1 W
i
L
= 0 μH
i
C
= 5 nF
i
STANDARD
U
= 32 V
i
l
= 300 mA
i
P
= n.a.
i
L
= 10 µH
i
C
= 5 nF
i
U
= 35 V
i
l
= 300 mA
i
P
= 1 W
i
L
= 0 µH
i
C
= 6 nF
i
25