Problem
The display shows Not enough UV.
Add!
The display shows Not enough oil.
Add!
The display shows Max. filling
time exceeded! Carry on?
The display shows External tank
empty or closed valve. Check!
The display shows Change the
equipment drier filter! Go on?
The display shows Change the vac‐
uum pump oil! Go on?
The display shows Printer not in
line! Carry on?
The display shows Error 01
The display shows Error 02
The display shows Error 03
The display shows Error 04
The display shows Error 09
The display shows Error 10
The display shows Error 12
The display shows Error 52
38
Possible cause
This message appears during the fill­
ing process if there is not enough UV
additive in the container to finish the
process.
Message that appears during the filling
process if there is not enough fresh oil
in the container to finish the process.
Message that appears during the filling
process if the set amount of refrigerant
cannot be filled.
Message that appears at the start or
during the filling of the internal refrig­
erant container if the set refrigerant
quantity cannot be attained.
This message appears when you
switch on the A/C service unit.
This message appears when you
switch on the A/C service unit.
Message indicates a printer fault.
Refrigerant was added before draining
was completed.
The air conditioning system is leaking.
There is still refrigerant in the air con­
ditioning system.
No data is coming from the refrigerant
scale.
It is not possible to lower the pressure
when flushing takes place.
Low pressure connector not connect­
ed to the flush container during flush­
ing.
It was not possible to reduce the pres­
sure sufficiently during the Software
test.
It was not possible to remove any re­
frigerant from the internal vessel dur­
ing the Software test.
No USB flash drive was found/recog­
nised.
Suggested remedy
Fill the UV additive container.
Top up the fresh oil container with a
suitable oil type.
Check that A/C service unit's connec­
tions are not blocked.
Check if the external refrigerant con­
tainer still contains enough refrigerant
or if the valves of the external refriger­
ant container are open.
Change the internal filter as soon as
possible (Changing the dryer filter on
page 32). To skip this, press 
TER
 for 3 seconds.
Change the vacuum pump oil as
soon as possible (Changing the vacu
um pump oil on page 34). To skip
this, press 
ENTER
 for 3 seconds.
Check if there is paper in the print­
er.
Check if the printer is switched on
(yellow LED must be lit constant­
ly).
Check that the cover is closed
properly.
Repeat the draining procedure; do not
interrupt it this time.
Fix the leak.
Check the scale.
Check air conditioner and connec­
tions for leaks, constrictions and
ice build­up.
Check pressure transducer cali­
bration.
Connect low pressure hose to the
flush box and open valve.
Residual pressure on the pressure
gauges?
Check pressure transducer cali­
bration.
Check internal bottle pressure.
Check the compressor and the
corresponding solenoid valves.
Check pressure transducer cali­
bration.
Check if the valve on the internal
vessel is open.
Check the RE valve.
Insert the USB flash drive.
Ensure that the USB flash flash
drive has been formatted with the
FAT32 file system.
EN­