Herunterladen Diese Seite drucken

Waeco AirCon Service ASC 6300 G LE Bedienungsanleitung Seite 29

Vorschau ausblenden Andere Handbücher für AirCon Service ASC 6300 G LE:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 102
Short selection
Free selection
Other selections
ENTER‐OK
22. Press 
ENTER
 to confirm.
23. If necessary, use the keypad to enter the data and press 
press 
ENTER
 to switch to the next program step.
24. Deselect Rec/Recycling phase using No (the setting flashes) and press 
25. Select Vacuum phase (the setting flashes) and press 
26. If necessary, use the keypad to enter the data and press 
press 
ENTER
 to switch to the next program step.
27. Select Filling phase (the setting flashes) and press 
28. Enter the refrigerant filling quantity (note the oil filling quantity of the compressor).
29. Then follow the instructions on the display: Select the setting (which then flashes) and press 
firm.
30. Select Process start by pressing 
After the filling is complete, you will be prompted to disconnect the hoses of the A/C service unit from the vehi­
cle air conditioning system.
31. Disconnect the service hoses and press 
The service hoses will now be drained. the A/C service unit is then ready for further use.
32. Put the valve caps of the vehicle air conditioning system back on the connections.
14 Service tasks
14.1 Leak test
Check the A/C service semiannual for leaks in accordance with the applicable legal requirements. Use an elec­
tronic leak detector for this purpose.
14.2 Resetting the counters
After you have finished one or more service tasks, you must reset the respective counters. To do this proceed as
follows:
1. Enter the Other selections – Service menu.
2. Enter the code 
.
7782
3. Use the cursor keys   or   to select the required entry and press 
4. Follow the display instructions, and press and hold the 
5. Switch back to the previous selection using 
The following counters can be reset:
R1234 from system
g.
STOP‐EXIT
R1234yf from system indicates how many grams of refrigerant have been extracted from air conditioning
systems using the menu item Short selection or Free selection since the last reset (see date).
R1234 from tank
g.
STOP‐EXIT
ENTER
ENTER
 to confirm.
ENTER
ENTER
ENTER
.
ENTER
 to confirm.
ENTER
STOP
.
07/03/17
4155
07/03/17
3395
 to confirm. If no data has to be entered,
ENTER
 to confirm.
 to confirm. If no data has to be entered,
 to confirm.
ENTER
 to confirm.
 button for 3 s.
    EN
ENTER
 to con­
29

Werbung

loading

Diese Anleitung auch für:

Aircon service asc 6400 g le