• Container for UV additive (11)
• Drained oil receptacle (12)
5. When the scales are relieved, press 
will flash. Once you have set the zero point, the selection menu for the scales appears again.
6. Return the containers to the operating positions: Reattach the containers for oil (10) and (12) and for the UV
additive (11) to the snap locks and close the cover (13).
7. Press 
STOP
14.5 Changing the dryer filter
1. In the basic menu use the cursor keys   or   to select Free selection.
Short selection
Free selection
Other selections
ENTER‐OK
2. Press 
ENTER
3. Skip the query requesting CAR DATA.
4. Select Rec/Recycling phase.
5. Set the Pressure increase Test time to 
6. Press 
ENTER
7. Deselect Vacuum phase using 
8. Press 
ENTER
9. Deselect Filling phase using 
10. Press 
ENTER
11. Select Process start.
12. Press 
ENTER
The service hoses will now be drained and the A/C service unit's basic menu will be activated. The compressor
has produced a slight internal vacuum so that the filter can be replaced with minimal refrigerant loss.
13. Switch off the A/C service unit.
14. Pull out the power supply plug.
15.
CAUTION! Health hazard
The following steps may only be performed by authorized personnel. Wear protective gloves and gog­
gles.
Unscrew the screw (D) from the holder, and pull the dryer filter straight out.
16. Replace the O­rings (E). Moisten new O­rings with refrigerant oil before installing.