ENTER‐OK
2. Press 
ENTER
 to confirm.
3. Use the cursor key   to select Service.
Refrigerant Test
Hybrid service
Service.
ENTER‐OK STOP‐EXIT
4. Press 
ENTER
 to confirm.
5. Enter the password 
2688
6. Use the cursor keys to activate any fields you need (dark fields are activated).
Oil bottle
150ml
250ml
UV bottle
150ml
250ml
7. Press 
ENTER
 to confirm.
8. Press 
STOP
 to access the standby menu..
12.11 Filling up the internal refrigerant container
When the A/C service unit is started for the first time, the A/C service unit displays Error 12, because the inter­
nal refrigerant vessel must be filled from an external refrigerant vessel with at least 2000 g of refrigerant.
1. Press 
STOP
 to confirm.
The current supply quantities are displayed in the standby menu.
2. Connect the external refrigerant vessel to the A/C service unit.
Note  Observe the instructions on the refrigerant vessels. Vessels for the R1234yf refrigerant have a
left­hand thread.
There are three different types of refrigerant vessel available:
• Refrigerant vessels without rising pipe: These refrigerant vessels have one connection. When filling the A/C
service unit, the connection must be on the bottom (turn the vessel upside down).
• Refrigerant vessels with rising pipe: These refrigerant vessels have one connection. When filling the A/C ser­
vice unit, the connection must be at the top (place the vessel upright).
• Refrigerant vessels with rising pipe: These refrigerant vessels have two connections. To top up the A/C ser­
vice unit, use the connection marked with L (= liquid). When filling the A/C service unit, the connection must
be at the top (place the vessel upright).
3. In the basic menu use the cursor keys   or   to select Other selections.
Short selection
Free selection
Other selections
ENTER‐OK
4. Press 
ENTER
 to confirm.
5. Use the cursor keys   or   to select Int. vessel filling.
Int. vessel filling
Flushing
Reset scales.
Service.
6. Press 
ENTER
 to confirm and follow the instructions in the display and provided here:
.
500ml
500ml
    EN
17