Herunterladen Diese Seite drucken

ULTIMATE SPEED USML 3.7 A1 Bedienungs- Und Sicherheitshinweise Originalbetriebsanleitung Seite 16

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
ERROR 4
Self test failed
ERROR 5
Under voltage
(input voltage
below 185 V)
ERROR 6
Over voltage
(input voltage is
over 275 V)
ERROR 7
Internal component
fault (relay)
ERROR 8
The temperature on
the Mains plug
is too high.
(temperature in the
mains plug
over 80 °C)
ERROR 9
Possible fault in
the car electronics
(diode)
ERROR 10
Short circuit cables
(CP to PE)
z Cleaning
Attention: The device must
not be submerged in water.
There is a risk of injury due
16
GB/IE/NI/CY/MT
Disconnect from the car and mains.
Then start the charging process again.
If the fault should occur again, return
the mobile charging station
dealer for repair.
Disconnect from the car and mains.
Wait until the mains voltage rises to
over 195 V. Then start the charging
process again.
Disconnect from the car and mains.
Wait until the mains voltage drops to
below 265 V. Then start the charging
process again.
Disconnect from the car and mains.
Return the mobile charging station
to the dealer for repair.
Disconnect from the car and mains.
Wait until the temperature in the mains
7
plug has dropped below 70 °C.
Then start the charging process again.
is
7
Disconnect from the car and mains.
Then start the charging process again.
Disconnect from the car and mains.
Then start the charging process again.
to electric shock if moisture
enters the device.
Do not use cleaners or solvents.
These could damage the device
to the
1
1

Werbung

loading