Herunterladen Inhalt Inhalt Diese Seite drucken

Retrofit Image Input And Output Signals; Input Signals - Fronius Ri Fb Inside/I Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für RI FB Inside/i:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Retrofit Image Input and Output Signals

Input Signals

The signals listed below are available from firmware V1.6.0 for all Inside/i sys-
tems.
Serial no.
E17 - E24
E25 - E31
Only in Job mode (E17 - E32):
E17 - E31
E33 - E40
E41 - E48
E49 - E56
E57–E64
E65 - E72
E73–E80
E81 - E88
E89 - E96
Signal designation
E01
Welding on
E02
Robot ready
E03
Operating mode bit 0
E04
Operating mode bit 1
E05
Operating mode bit 2
E06
E07
E08
E09
Gas test
E10
Wire forward
E11
Wire backward
E12
Error quit
E13
Position search
E14
Purge welding torch
E15
E16
Job number
Program number
E32
Welding simulation
Job number
E32
Welding simulation
Output set value - Low byte
Output set value - High byte
Arc length correction, set value
Low byte
Arc length correction, set value
High byte
Pulse or dynamic correction
Range
Action
High
High
See table
Value
High
range for opera-
High
ting modes
on
page
50
High
High
High
High
High
High
High
0 to 99
1 to 127
High
0 to 999
High
0 to 65535
(0 to 100%)
0 to 65535
(-30 to +30%)
0 to 255
(-5 to +5%)
49

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ri mod/i cc-m40 ethernet/ip-2p

Inhaltsverzeichnis