Address
relative
absolute
BIT
12,
6
0-7
96-111
13
14,
7
0-7
112-127
15
16
0-7
128-135
8
17
0-7
136-143
18
0-7
144-151
9
19
0-7
152-159
20
0-7
160-167
10
21
0-7
168-175
22
0-7
176-183
11
23
0-7
184-191
Signal
With the welding process
MIG/MAG pulse synergic,
MIG/MAG standard syner-
gic,
MIG/MAG PMC,
MIG/MAG LSC,
CMT:
Arclength correction
With the welding process
MIG/MAG standard manu-
al:
Welding voltage
With the Job mode:
Arclength correction
With the welding process
ConstantWire:
Hotwire current
With the welding process
MIG/MAG pulse synergic,
MIG/MAG standard syner-
gic,
MIG/MAG PMC,
MIG/MAG LSC,
CMT:
Pulse-/dynamic correction
With the welding process
MIG/MAG standard manu-
al:
Dynamic
Wire retract correction
Welding speed
Process controlled correc-
tion
Range
-10.0 to
SINT16
10.0
[Steps]
0.0 to
UINT16
6553.5 [V]
-10.0 to
SINT16
10.0
[Steps]
0.0 to
UINT16
6553.5 [A]
-10.0 to
SINT16
10.0
[Steps]
0.0 to 10.0
UINT16
[Steps]
0.0 to 10.0
UINT16
[Steps]
0.0 to
UINT16
1000.0
[cm/min]
See table
Value
range for Pro-
cess controlled
correction
on pa-
43
ge
Process
image
10
ü
ü
10
10
10
10
ü
ü
10
10
ü
10
ü
ü
ü
41