« SETUP » MENU (access via scroll wheel)
CONSUMABLES
AIR TEST
TORCH LENGHT
LOG BOOK
EN FR DE IT...
UNITS
LOCKING
EXIT
COUNTERS
1
ELECTRODE
0 Cycl./
2
TIP
0 Cycl./
RESETS
EXIT
RESETTING THE COUNTERS
26
NEOCUT 105 / 125
6.0m
3
AUTO
105 A
6.0m
5.2
bar
105 A
optimal
6.0m
5.2
bar
105 A
+0.2
.0H
This tool counts the number of cycles and the nozzle and electrode cutting time:
1- Number of cycles and cumulative use time of the electrode
2- Number of cycles and cumulative use time of the nozzle
.0H
3- Meter reset menu
3
4- Go back to the Setup menu
4
1
RESET ELECTRODE
2
RESET TIP
RESET ALL
3
EXIT
4
To switch the pressure setting to manual mode, a long press on the scroll wheel
is required: a countdown will start next to the padlock.
Releasing the scroll wheel during the countdown cancels the pressure unlocking
action.
At the end of the countdown, the following screen will appear:
- the padlock is open (symbolizing that the adjustment is possible)
- the current pressure is displayed (the value corresponds to the value used in
automatic mode)
- A bar-graph with a value gives the trend (the text «optimal» is displayed when
the chosen value corresponds perfectly to the value that would be used in auto-
matic mode).
Example of a pressure setting higher than the optimum value of +0.2bar
To return to automatic setting, press and hold down the scroll wheel: a countdown
will start next to the padlock.
At the end of the countdown, the setting will be in «AUTO» with the padlock
locked.
In order to have a representative count, it is necessary to reset the counter(s) of
the consumable(s) being replaced.
The counter reset menu offers :
1- Zeroing of the electrode counters
2- Zeroing of the nozzle counters
3- Zeroing of all counters
4- Go back to the previous screen