Load Transfer Ribbon
NOTICE!
For the thermal transfer printing method it is necessary to load a ribbon, otherwise when using the print module in
direct thermal print it is not necessary to load a ribbon. The ribbons used in the print module have to be at least the
same width as the print media. In case the ribbon is narrower than the print media, the printhead is partly
unprotected and this could lead to early wear and tear.
E
D
C
Open the cover of print module.
Open the printhead (C) by turning the red pressure lever (D) anticlockwise.
CAUTION
!
Risk of scraping when inserting the transfer ribbon res. when removing the used transfer ribbon!
Be careful with the spring steel plate edges!
Load the transfer ribbon roll (A) with outer winding onto the unwinding roll (B).
Place an empty ribbon roll on the rewinding roll (E) and lead the transfer ribbon below the printhead.
Fix the ribbon with an adhesive tape in rotating direction at the empty roll of the rewinding roll (E).
Pay attention to the rotation direction of transfer ribbon rewinder anticlockwise.
In order to move the printhead (C) down, turn the red pressure lever (D) in clockwise direction until it locks.
Close the cover of the print module.
NOTICE!
As for the electrostatic unloading the thin coating of the thermal printhead or other electronic parts can be damaged,
the transfer ribbon should be antistatic.
The use of wrong materials can lead to print module malfunctions and the guarantee can expire.
CAUTION
!
Impact of electrostatic material on people!
Use antistatic transfer ribbon because electrostatic discharge can occur when removing.
118
A
B
English
NOTICE!
Before a new transfer ribbon roll is
loaded, the printhead must be cleaned
using printhead and roller cleaner
(97.20.002).
The handling instructions for the use
of Isopropanol (IPA) must be
observed. In the case of skin or eye
contact, immediately wash off the fluid
thoroughly with running water. If the
irritation persists, consult a doctor.
Ensure good ventilation.