Installation
● Attach the switching cabinet (1) and the junction box (5) to the wall.
● Installation of the radiation chamber (6) in the piping can be carried
out horizontally (with venting screw in upper position) or vertically.
● When carried out horizontally, the flow direction can be left to right
or right to left.
● When carried out vertically, the flow direction has to be from below
to above.
● Connect protection earth cable to bolt on top of the radiation cham-
ber.
● Connect the cables from the junction box to the switching cabinet.
● To install the temperature sensor (10), the most upper bushing (11)
must be used.
● Screw in the temperature sensor by hand, until the sensor-surface
has contact to the pipe.
NOTE
If the surface of the temperature sensor
has no contact to the pipe, the unit can
be destroyed!
● Connect the cable from the junction box (5) with the temperature
sensor (10).
● Connect the switching cabinet (1) with the power supply.
● Connect potential equalization cable at the clamp (red arrow).
6.1
Installation diagram
10
11
EN
1
5
Lamp connection cables
11
6
33