Herunterladen Diese Seite drucken

BWT Bewades MQ-LC Einbau- Und Bedienungsanleitung Seite 35

Uv-desinfektionsanlage zur badewasseraufbereitung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1
5
2
● In case of horizontal installation, the unit has to be vented via the
bleeder (red arrow).
6.3
Modification of the cleaning device
The manual cleaning device is attached to the permanently welded
flange (1) at the factory.
On the cleaning flange (2) on the opposite side, a blind plug (3) is screwed
into the optional cleaning suspension.
If, due to structural circumstances, it is necessary to convert the cleaning
device to the side of the cleaning flange (2), proceed as follows:
Remove the dummy plug (3) from the cleaning flange (2).
Unscrew the cleaning device (4) clockwise from the thread on the
welded-on flange (1).
Screw the cleaning device (4) into the thread of the cleaning flange (2).
Screw the dummy plug (3) into the thread of the firmly welded flange (1).
4
3
EN
1
4
3
5
35

Werbung

loading