Quartz glass tube
34
Noses of the
Centring disk
6.2
Installation of lamps
● Unscrew the lamp protectors (2 screws per lamp).
NOTE
► UV lamps must not be touched with bare
hands!
►Use cloth gloves!
►Fingerprints burn into the glass and can lead to
failures. Fingerprints must be removed with a
cloth soaked in alcohol before installation!
►The minimum burning time of the lamp is
10 min. A shorter duty cycle leads to faults (the
lamp no longer ignites).
● Remove the lamp from the packaging.
● UV lamps are only allowed to be touched wearing cloth gloves.
● Due to the centring disks on the lamps, they can only be removed
and inserted in one direction.
● The „noses" of the two centring disks must always be orientated in
the same direction.
● Attach the centring disk and secure with the spring.
● Insert the lamp on the side of the screwed-on cover.
● Connect the lamp connection cables and mount the caps.
● Open the shut off valves.