Herunterladen Diese Seite drucken

Endress+Hauser procom DZL 363 II2G Ex-Dokumentation Zu Den Betriebsanleitungen Seite 24

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

en
Warning!
Fig. 4
Label on the electronics unit of
Promass 63
Fig. 5
Nameplate for the electronics
housing Promass 63
Ex version
Fig. 6
Nameplate for the sensors
Promass A/F/I/M
Ex version
10
Exchange of electronics unit
These four positions must match the last four
positions of the order code (see Fig. 5)
Modul designation
63XMOD-
39
A9
1239
GLM9
Possible contents in the order
code
Instrument identification
Electronics housing Promass 63 (example):
Production location
Instrument group and instru-
ment category according
to Directive 94/9/EC
Labelling of the ignition pro-
tection type and explosion
group for the electronics
unit.
Ambient
temperature range
Labelling of the ignition pro-
tection type and explosion
group for the electronics
housing Promass 63
Sensors Promass A/F/I/M (example):
Production location
Instrument group and instru-
ment category according
to Directive 94/9/EC
Labelling of the ignition
protection type and
explosion group for the
sensors Promass A/F/I/M
Warning!
The four positions on the electronics unit
label of Promass 63 must match the last
four positions of the order code on the
electronics housing nameplate
(see Fig. 5), other-wise the electronics
unit may not be installed. Before reapply-
ing power, the housing cover must be
tightly closed.
Notified body for Q-Control:
TÜV-Hannover/Sachsen-Anhalt e.V.
CH-4153 Reinach
ENDRESS+HAUSER
PROMASS 63
Order Code:
XXXXXX-XXXXXXXXXXX
XX XXXXXX XX
Ser.No.:
16-62VDC/20-55VAC
15VA/W
50-60Hz
I-OUT,AUX-INP/HILFSEING
II2G
Typ Promass
EEx de ib IIC T2-T6
SYST EEx ib/ia IIC/IIB
EEx d ib IIC T2-T6
BVS 96.D.2022 X
Tamb/Tumg:-20°C..+60°C
DMT 99 ATEX E 015 X
PRO-LINE Housing/Gehaeuse
EEx d IIC/EEx de IIC
BVS 95.D.2010 U
XA006D/
i
DMT 98 ATEX E 029 U
06/../....
After de-energizing, delay 10 Minutes before opening!
Nach dem Abschalten 10 Minuten warten vor dem Oeffnen!
Pat.US 5,479,007 5,648,616
Pat.UK EP 618 680
Pat.UK EP 261,435 262,573
Pat.US 4,768,384 4,801,897
Notified body for Q-Control:
TÜV-Hannover/Sachsen-Anhalt e.V.
CH-4153 Reinach
ENDRESS+HAUSER
PROMASS A
XXXXXX-XXXXXXXXXXX
Order Code:
XX XXXXXX XX
Ser.No.:
1.5328/0000
K-factor:
DN02 1/2" TRICLAMP
160bar
Pmax.:
Werkstoffe:
1.5328/0000
150°C
Materials:
TMmax.:
Dichtekalibrierung:
+/-0.020g/cc
Density calibration:
5P-CAL, 3.1B
25 bar Container
XA006D/
II2G
EEx ib IIC T2-T6
i
06/../....
BVS 96.D.2022 X
DMT 99 ATEX E 015 X
Tamb/Tumg:-20°C..+60°C
Pat.US 5,705,754
Ambient temperature
range
Procom DZL 363 with Promass 63
When exchanging the
electronics unit, these last
four order code positions
0032
must match the four positions
on the electronics unit label
(see Fig. 4)
1999
Year of manufacture
IP67
Labelling of the ignition pro-
tection type and explosion
group for the measuring
system Promass 63
Corresponding Ex
documentation
Warning
0032
Year of manufacture
1999
IP67
Corresponding Ex
documentation
Endress+Hauser

Werbung

loading