Endress+Hauser procom DZL 363 II2G Ex-Dokumentation Zu Den Betriebsanleitungen Seite 16

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

en
PROMASS 63
Nicht unter
Spannung öffnen.
Keep cover tight while
circuits are alive.
Ne pas ouvrir l´appareil
sous tension.
Sensor A
PROMASS 63
Nicht unter
Spannung öffnen.
Keep cover tight while
circuits are alive.
Ne pas ouvrir l´appareil
sous tension.
Sensor I
Electronics housing Promass 63 in [EEx ib] IIC/IIB
PRO-LINE Ex d housing in EEx d IIC resp. EEx de IIC
(An appropriate cable entry is to be selected, depending
on the explosion protection type.)
Sensor in EEx ib IIC:
• PROMASS A
DN 1...4
• PROMASS F
DN 8...50
• PROMASS I
DN 8...40
• PROMASS M
DN 8...50
Sensor in EEx ib IIB:
• PROMASS F
DN 80...100
• PROMASS I
DN 50
• PROMASS M
DN 80
For ambient and fluid temperature ranges, and
temperatur class, see page 4
2
Hazardous area
II2G (ATEX)
PROMASS 63
Nicht unter
Spannung öffnen.
Keep cover tight while
circuits are alive.
Ne pas ouvrir l´appareil
sous tension.
Sensor F
PROMASS 63
Nicht unter
Spannung öffnen.
Keep cover tight while
circuits are alive.
Ne pas ouvrir l´appareil
sous tension.
Sensor M
Zone 1 (CENELEC)
Hazardous area
resp. DN 40 "FB"
DZL 363 version:
Racksyst cassette
(IP 20)
DZL 363 version:
Panel mounted
housing (IP 20 /
front door IP 54)
DZL 363 version:
Field housing
(IP 65)
Zone 2 (CENELEC)
For installation in a rack or a panel in Zone II3G or Zone 2,
enclosure protection according to EN 60529 is required:
– outdoor use ≥ IP 54
– indoor use ≥ IP 40
Transmitter Procom DZL 363 for II3G/Zone2:
II(2)G [EEx ib] IIC (intrinsically safe signal current cirquit)
II3G EEx nW [L] IIC T4 (prEN)
Ex nAC IIC T4 (IEC)
The maximum ambient temperature is +60°C
Transmitter Procom DZL 363 for the safe area:
II(2)G [EEx ib] IIC
For the non-intrinsically safe signal circuit, the following
applies:
U
= 260 V
max
I
= 500 mA
max
Procom DZL 363 with Promass 63
Safe area
II3G (ATEX)
➅ ➇
ENDRESS+HAUSER
PROCOM DZL
363
1
2
3
F1
F2
F3
E
>3s
ENDRESS+HAUSER
PROCOM DZL
1
2
3
➅ ➇
DZL 363 version:
Racksyst cassette
(IP 20)
E+H
ENDRESS+HAUSER
PROCOM DZL
363
1
2
3
F1
F2
F3
E
>3s
➅ ➇
DZL 363 version:
Panel mounted
PROCOM DZL
363
housing (IP 20 /
1
2
3
front door IP 54)
1
2
3
DZL 363 version:
Field housing
(IP 65)
Safe area
and
(see page 7)
Endress+Hauser
➆ ➇
363
F1
F2
F3
E
>3s
➆ ➇
E+H
ENDRESS+HAUSER
PROCOM DZL
363
1
2
3
F1
F2
F3
E
>3s
➆ ➇
PROCOM DZL
363