en
Explanation of Promass I
DN 16 = DN 15 "FB"
DN 26 = DN 25 "FB"
DN 41 = DN 40 "FB"
"FB" = Full bore
4
Temperature tables of Promass 63
Sensor (compact version)
at Ta = 50 °C
Promass F DN 8/15/25/40/50/80/100
Promass M DN 8/15
Promass M DN 25/40/50
Promass M DN 80
at Ta = 60 °C
Promass A DN 1/2/4
Promass F DN 8/15/25/40/50
Promass F DN 80/100
Promass I DN 8/15/16/25
Promass I DN 26/40/41/50
Promass M DN 8/15
Promass M DN 25/40/50
Promass M DN 80
The minimum fluid temperature is –50 °C (for a minimum fluid temperature below
–20 °C, the minimum ambient temperature is –10 °C).
Sensor (remote version)
at Ta = 50 °C
Promass M DN 8/15
at Ta = 60 °C
Promass A DN 1/2/4
Promass F DN 8/15/25/40/50
Promass F DN 80/100
Promass I DN 8/15/16/25
Promass I DN 26/40/41/50
Promass M DN 8/15
Promass M DN 25/40/50
Promass M DN 80
Promass A DN 1/2/4
Promass F DN 8/15/25/40/50
Promass F DN 80/100
Promass I DN 8/15/16/25/26/40
Promass I DN 50
Promass M DN 8/15/25/40/50
Promass M DN 80
Electronics housing (remote version)
In the PRO-LINE EEx d electronics housing, PROMASS 63****-*****B***** resp.
PROMASS 63****-*****C***** have the T6 temperature class up to an ambient
temperature of Ta = 60 °C.
Procom DZL 363 with Promass 63
Max. fluid temperature [°C] in
T6
T5
T4
60
95
130
60
95
130
65
95
130
65
80
110
Max. fluid temperature [°C] in
T6
T5
T4
60
95
130
60
95
100
60
75
100
60
95
130
70
85
120
–
95
100
65
95
100
65
80
100
Max. fluid temperature [°C] in
T6
T5
T4
55
95
130
Max. fluid temperature [°C] in
T6
T5
T4
60
95
130
60
95
130
60
75
110
60
95
130
70
85
120
–
95
130
65
95
130
65
80
110
Min. fluid temperature [°C] in
Use in gas group IIC
-90
-120
*
-50
*
-50
*
* not available for this gas group
T3
T2
170
200
150
–
150
–
150
–
T3
T2
150
200
–
–
–
–
150
–
150
–
–
–
–
–
–
–
T3
T2
150
–
T3
T2
150
200
170
200
170
200
150
–
150
–
150
–
150
–
150
–
Use in gas group IIB
-120
-120
-50
-50
-50
-50
-50
Endress+Hauser