Procom DZL 363 with Promass 63
Electrical data
Procom DZL 363 with DoS interface to Promass 63
(Procom DZL 363-15****)
Racksyst-/
Voltage:
panel mounted
AC 85...260 V
housing:
d30 / z30 / d32
L1: d30 or 2
Field housing:
N: d32 or 3
1 / 2 / 3
Power consumption:
Racksyst-/
corresponds with Promass 63
panel mounted
Terminal 20 (DoS+; A data)
housing:
Terminal 21 (DoS-; B data)
d8 (DoS+)
d10 (DoS-)
(see next page)
Field housing:
80 (DoS+)
81 (DoS-)
z2 / z4
Ground connection (at least two of the ground
z16 / z32
terminals must be connected to safety ground)
Procom DZL 363 with Dx interface to Promass 63
(Procom DZL 363-10****)
Racksyst-/
Voltage:
panel mounted
AC 85...260 V
housing:
d30 / z30 / d32
L1: d30 or 2
Field housing:
N: d32 or 3
1 / 2 / 3
Power consumption:
Racksyst-/
corresponds with Promass 63
panel mounted
Terminal 22 (Dx+; A data)
housing:
Terminal 23 (Dx-; B data)
d2 (Dx+)
d4 (Dx-)
(see next page)
Field housing:
80 (Dx+)
81 (Dx-)
z2 / z4
Ground connection (at least two of the ground
z16 / z32
terminals must be connected to safety ground)
Procom DZL 363 with EEx i Dx interface to Promass 63
(Procom DZL 363-30****)
Racksyst-/
Voltage:
panel mounted
AC 85...260 V
housing:
d30 / z30 / d32
L1: d30 or 2
Field housing:
N: d32 or 3
1 / 2 / 3
Power consumption:
Racksyst-/
corresponds with Promass 63
panel mounted
Terminal 22 (Dx+; A data)
housing:
Terminal 23 (Dx-; B data)
d2 (Dx+)
d4 (Dx-)
(see next page)
Fieldhousing:
80 (Dx+)
81 (Dx-)
z2 / z4
Ground connection (at least two of the ground
z16 / z32
terminals must be connected to safety ground)
Endress+Hauser
Functional value
AC 20...55 V or
DC 20...62 V
L+: d32 or 3
L-: z30 or 1
35 VA / 35 W
Functional value
AC 20...55 V or
DC 20...62 V
L+: d32 or 3
L-: z30 or 1
35 VA / 35 W
Functional value
AC 20...55 V or
DC 20...62 V
L+: d32 or 3
L-: z30 or 1
35 VA / 35 W
Safety value
U
= 260 V
max
For connecting devices with U
= 260 V and
max
I
= 500 mA.
max
Safety value
U
= 260 V
max
For connecting devices with U
= 260 V and
max
I
= 500 mA.
max
Safety value
U
= 260 V
max
Max. values:
U
=
8,7 V
O
I
=
183 mA
O
P
=
398 mW
O
linear curve
Maximum external inductance and capacitance
are in the table below:
IIC
L
/ mH
0,55
o
C
/ nF
5,9
o
Racksyst cassette and
panel mounted housing
ENDRESS+HAUSER
PROCOM DZL
363
1
2
3
F1
F2
F3
E
>3s
Dx version
DoS version
Field housing
(valid for all three versions)
PROCOM DZL
363
1
2
3
20 22 30 32 34 40 42 50 52 60 63 66 70 73 76
21 23 31 33 35 41 43 51 53 61 64 67 71 74 77
62 65 68 72 75 78
1 2 3
Terminal compartment
IIB
4,5
50
en
E+H
ENDRESS+HAUSER
PROCOM DZL
363
1
2
3
F1
F2
F3
E
>3s
Mains board
d2
d4
d8
d10
L1
L-
N
L1+
80 81
7