Procom DZL 363 with Promass 63
Labelling
Transmitter Procom DZL 363
(non-intrinsically safe signal current circuit connection to Promass 63)
Procom DZL 363-*.****
Transmitter Procom DZL 363
(intrinsically safe signal current circuit connection to Promass 63)
Procom DZL 363-..****
Procom DZL 363: [EEx ib] IIC/IIB
Measuring system Promass 63
(compact version, non-intrinsically safe signal current circuit connection to DZL 363)
Promass 63****-**********.
Promass 63 A
DN 1...4:
Promass 63 F
DN 8...50:
Promass 63 F
DN 80...100:
Promass 63 I
DN 8...40:
Promass 63 I
DN 50 resp. DN 40 "FB": EEx de ib IIB T3-T6 or EEx d ib IIB T3-T6
Promass 63 M
DN 8...50:
Promass 63 M
DN 80:
Measuring system Promass 63 EEx i
(compact version, intrinsically safe signal current circuit connection to DZL 363)
Promass 63****-**********.
Promass 63 A
DN 1...4:
Promass 63 F
DN 8...50:
Promass 63 F
DN 80...100:
Promass 63 I
DN 8...40:
Promass 63 I
DN 50 resp. DN 40 "FB": EEx de [ib] IIB T3-T6 or EEx d [ib] IIB T3-T6
Promass 63 M
DN 8...50:
Promass 63 M
DN 80:
Electronics housing Promass 63
(remote version, non-intrinsically safe signal current circuit connection to DZL 363)
Promass 63****-**********.
Promass 63: EEx d e [ib] IIC/IIB T6 resp. EEx d [ib] IIC/IIB T6
Electronics housing Promass 63 EEx i
(remote version, intrinsically safe signal current circuit connection to DZL 363)
Promass 63****-**********.
Promass 63: EEx d e [ib] IIC/IIB T6 resp. EEx d [ib] IIC/IIB T6
Meßaufnehmer Promass
(Getrenntausführung)
Promass 63 A
DN 1...4:
Promass 63 F
DN 8...50:
Promass 63 F
DN 80...100:
Promass 63 I
DN 8...40:
Promass 63 I
DN 50 resp. DN 40 "FB": EEx [ib] IIB T3-T6
Promass 63 M
DN 8...50:
Promass 63 M
DN 80:
Endress+Hauser
0 → Dx signal current circuit, data only, two-wire connection
(this corresponds to code L with Promass 63)
5 → DoS signal current circuit, two-wire connection,
data incl. power supply for Promass 63
(this corresponds to code G with Promass 63)
0 → Dx signal current circuit, data only, two-wire connection
(this corresponds to code M with Promass 63)
3 → [EEx ib] IIC/IIB
G → DoS signal current circuit EEx e connection
(this corresponds to code 5 with Procom DZL 363)
L → Dx signal current circuit EEx e connection
(this corresponds to code 0 with Procom DZL 363)
EEx de ib IIC T2-T6 or EEx d ib IIC T2-T6
EEx de ib IIC T2-T6 or EEx d ib IIC T2-T6
EEx de ib IIB T2-T6 or EEx d ib IIB T2-T6
EEx de ib IIC T3-T6 or EEx d ib IIC T3-T6
EEx de ib IIC T3-T6 or EEx d ib IIC T3-T6
EEx de ib IIB T3-T6 or EEx d ib IIB T3-T6
M → EEx i Dx interface with Procom DZL 363
(this corresponds to code 0 and 3 with Procom DZL 363)
EEx de [ib] IIC T2-T6 or EEx d [ib] IIC T2-T6
EEx de [ib] IIC T2-T6 or EEx d [ib] IIC T2-T6
EEx de [ib] IIB T2-T6 or EEx d [ib] IIB T2-T6
EEx de [ib] IIC T3-T6 or EEx d [ib] IIC T3-T6
EEx de [ib] IIC T3-T6 or EEx d [ib] IIC T3-T6
EEx de [ib] IIB T3-T6 or EEx d [ib] IIB T3-T6
G → DoS signal current circuit EEx e connection
(this corresponds to code 5 with Procom DZL 363)
L → Dx signal current circuit EEx e connection
(this corresponds to code 0 with Procom DZL 363)
M → EEx i Dx interface with Procom DZL 363
(this corresponds to code 0 and 3 with Procom DZL 363)
EEx [ib] IIC T2-T6 or EEx [ib] IIB T2-T6
EEx [ib] IIC T2-T6
EEx [ib] IIB T2-T6
EEx [ib] IIC T3-T6
EEx [ib] IIC T3-T6
EEx [ib] IIB T3-T6
en
Fig. 1
Transmitter Procom DZL 363
Fig. 2
Compact version
Promass 63 measuring system
Fig. 3
Remote version
Promass 63 electronics housing
and sensor