Procom DZL 363 with Promass 63
Sensor A
Sensor F
Sensor I
Sensor M
Elektronics housing Promass 63 in [EEx ib] IIC/IIB
PRO-LINE Ex d housing in EEx d IIC resp. EEx de IIC
(An appropriate cable entry is to be selected, depending
on the explosion protection type.)
Sensor in EEx ib IIC:
• PROMASS A
DN 1...4
• PROMASS F
DN 8...50
• PROMASS I
DN 8...40
• PROMASS M
DN 8...50
Sensor in EEx ib IIB:
• PROMASS F
DN 80...100
• PROMASS I
DN 50
• PROMASS M
DN 80
The maximum permitted cable length is 120 m when using
cable type (6 Li9YCY 0,38 mm
reasons, the max. cable length is limited to 20 m.
Endress+Hauser
Hazardous area
II2G (ATEX)
Zone 1 (CENELEC)
Hazardous area
resp. DN 40 "FB"
2
) FCY, however for signal
Nicht unter
Spannung öffnen.
Keep cover tight while
circuits are alive.
Ne pas ouvrir l´appareil
sous tension.
PROMASS 63
Nicht unter
Spannung öffnen.
Keep cover tight while
circuits are alive.
Ne pas ouvrir l´appareil
sous tension.
PROMASS 63
Nicht unter
Spannung öffnen.
Keep cover tight while
circuits are alive.
Ne pas ouvrir l´appareil
sous tension.
PROMASS 63
Nicht unter
Spannung öffnen.
Keep cover tight while
circuits are alive.
Ne pas ouvrir l´appareil
sous tension.
PROMASS 63
For ambient and fluid temperature ranges, and
temperatur class, see page 4
For installation in a rack or a panel in Zone II3G or Zone 2,
enclosure protection according to EN 60529 is required:
– outdoor use ≥ IP 54
– indoor use ≥ IP 40
Transmitter Procom DZL 363 for II3G/Zone2:
II(2)G [EEx ib] IIC (intrinsically safe signal current cirquit)
II3G EEx nW [L] IIC T4 (prEN)
Ex nAC IIC T4 (IEC)
The maximum ambient temperature is +60°C
Transmitter Procom DZL 363 for the safe area:
II(2)G [EEx ib] IIC
For the non-intrinsically safe signal circuit, the following applies:
U
= 260 V
max
I
= 500 mA
max
II3G (ATEX)
➆ ➈
ENDRESS+HAUSER
PROCOM DZL
363
1
2
3
F1
F2
F3
E
>3s
DZL 363 version:
Racksyst cassette
(IP 20)
➆ ➈
DZL 363 version:
Racksyst cassette
(IP 20)
E+H
ENDRESS+HAUSER
PROCOM DZL
363
1
2
3
F1
F2
F3
E
>3s
DZL 363 version:
Panel mounted
housing (IP 20 /
front door IP 54)
➆ ➈
DZL 363 version:
Panel mounted
housing (IP 20 /
PROCOM DZL
363
1
front door IP 54)
2
3
DZL 363 version:
Field housing
(IP 65)
DZL 363 version:
Field housing
(IP 65)
Zone 2 (CENELEC)
and
(see page 7)
en
Safe area
➇ ➈
ENDRESS+HAUSER
PROCOM DZL
363
1
2
3
F1
F2
F3
E
>3s
➇ ➈
E+H
ENDRESS+HAUSER
PROCOM DZL
363
1
2
3
F1
F2
F3
E
>3s
➇ ➈
PROCOM DZL
363
1
2
3
Safe area
3

Werbung

loading