9. Reset on wall/authorisation reader
2.1/4.1
9 Reset on wall/authorisation
10 Signalling of wall/authorisation
Feedback signals
Blue LED
Flashing red LED
34 / 72
reader 2.1/4.1
16
The reset (=cold start) is required, among other things,
to:
Delete stored data
Read facility card with new object code
Proceed as follows:
ü
Operating voltage disconnected.
1. Bridge pins 6 and 4 (short circuit) on the debug
connector with a piece of wire.
17
2. Switch on the operating voltage.
3. Wait for the reset to start.
The red and green LEDs flash rapidly (orange).
9
4. After the first flash, remove the jumper.
5. Wait for the reset (may take several seconds).
When the reset is complete, the blue LEDs light up.
9
If no LEDs are lit, check the electrical connection.
reader 2.1/4.1
PegaSys Wall/authorisation reader
Meaning
Operating voltage switched on,
wall/authorisation reader ready
for operation