Simons Voss Technologies PegaSys 2.1 Kurzanleitung Seite 32

Wandleser und berechtigungsleser
Vorschau ausblenden Andere Handbücher für PegaSys 2.1:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7. Installation of wall/authorisation
reader 2.1/4.1
32 / 72
9
Screw heads must be flush with the mounting
plate.
6
4. Pass the cable through the prepared wall and
through the mounting plate.
7
5. Place the reader on the mounting plate.
8
6. Set the address for the RS485 bus on the IO con-
nector if necessary.
9
IMPORTANT
Unique addresses on the RS485 bus
Each reader/IO board combination on the RS485 bus
must be clearly addressed.
1. Do not assign an address twice.
2. Use a maximum of two reader/IO boards per
RS-485 bus.
If both reader and IO board are equipped with a DIP
9
switch, the DIP switch of the IO board has priority.
7. On the IO controller supplied, use the jumper next
to the relay to set whether the relay contact should
be open or closed in idle state.
10
8. Mount the supplied IO connector in a protected
location, e.g. with the optionally available Hensel
box (item no. 3050121300).
11
9. Connect the reader cables to the IO connector.
12
PegaSys Wall/authorisation reader
2.1 and 4.1
EN