3.2. Tightness Test
After commissioning, all screw connections are to be checked
for tightness.
ITT Water & Wastewater do not assume any responsibility for
water damage(s)!
4. Software
The Aquada units (Proxima & Maxima) are equipped with a monitoring unit which
is controlled by a micro-controller. The Aquada unit (Altima) is equipped with an
visual function control (section 3.1.1.)
• After first commissioning 365 is shown on the display and the LED „days of use"
is lit up (Proxima, Maxima)
• Press the RESET button for approx. 10 sec. (directly after switching on)
• The initialization time is 5 minutes
• After this the unit is ready for operation and the outlet solenoid valve is switched
on
• The display of the Maxima version now changes every 2 seconds from the display
of the days of use to the display of the UV intensity. The Proxima display remains
showing the days of use. In normal rating operation, the intensity is shown by HI
in the display.
• The display always shows the remaining number of days of use