GROUP J -
141
L.b. .S.
diSAb.
autom.
manu.
142
L.b. t.
Sets the maximum time span allowed for a process
variation to occur before the loop break error is
triggered. The minimum delta variation considered is
set in P_143 (L.b. b. )
00:01..99:59 mm:ss, Default: 02:00.
143
L.b. b.
Sets the minimum delta process variation required to
occur (within the timeframe set in P_142 Lb. t. ) in order
to avoid a loop break error
1..+10000 [digit
sensors), Default: 100.
144÷148
Reserved parameters - Group J.
86 - ATR144 - User manual
- Loop Break
Lo.br.
Loop Break State
Loop break disabled. (Default)
Loop break enabled with automatically
calculated time and band.
Loop break enabled with time (par. Lb. t. )
And band (par. Lb. b. ) entered by the user.
Loop Break Time
Loop Break Band
1 p. 101
Reserved Parameters - Group J
] (degrees.tenths for temp.