To fill the spa, you can use a garden hose, or provide connec-
tions to the plumbing system of the home as shown in
detail 11.
IMPORTANT: The solenoid valve on the compensation
tank (required for automatic water level filling) must be
permanently connected to the water supply via a rigid
pipe system.
Any connections to the drinking water supply net-
work (other than those suggested) must be made in
compliance with standard EN1717, adopting anti-
pollution protective met hods "AA", "AB" or "AD". For
further information, we recommend you contact your
water supply company and/or your plumber.
CAUTION: (IEC 60335-1) The pressure of the hydraulic
system feeding the equipment must not exceed 600
kPa (6 bar); if the equipment has one or more solenoid
valves for the water supply, the pressure must be min-
imum 35 kPa (0.35 bar).
If included, connection of the blower (
the spa must be made by creating a siphon (
tail B) as near as possible to the spa itself. This will prevent situa-
tions where the water might reach the blower and compromise
its operation.
Preparing the electrical connections
For preparations/measuring the electric system that will
supply the spa, please note that powers in kW indicated in the
"Maximum absorption of the System" table are to be consid-
ered as maximum absorbed powers during operation.
Spa-pack "booster kit": in the instance where a spa-pack "boost-
er kit" is also installed, a separate supply line must be provided and
it must be connected to the main spa-pack; refer to the relative
documentation.
three-phase version
The installer must use cables with a suitable cross-section (see
the minimum cross-section table) protected with a Ø 32 mm
sheath at the end and/or tubes or pipes along the section con-
necting to the main switch, not below type H 05 VV-F (multipo-
lar) or H07 V-K (unipolar).
without
Power supply
heating system
Volt
Hertz
mm
220 - 240 3~
50/60
2,5
(*)
380 -415 3N~ 50/60
1,5
(*): special standard (not valid for Europe)
The cable cross-section measurements must be chosen ac-
cording to the system consumption, as well as the cable
Jacuzzi Europe S.p.A. © 2023
2-2a, detail 17) to
2-2a and 6, de-
with
heater (12 kW)
2
mm
2
10
4
routes and distances, the chosen protective systems, and
2-2a,
the specific standards for fixed electrical systems in force in
the country where the hot tub is installed.
single-phase version
The electrical connection can be made as follows:
- single-phase line (220-240V 1~)
- three-phase line consisting of two phase conductors + a neu-
tral conductor (380-415V 2N~)
- three-phase line consisting of three phase conductors + a neu-
tral conductor (380-415V 3N~)
The installer must use cables with a suitable cross-section (see
the minimum cross-section tables) protected with tubes or pipes
along the section connecting to the main switch, not below type
H 05 VV-F (multipolar).
Power supply
Volt
220 - 240 1N~ 50/60
380 -415 3N~ 50/60
The cable cross-section measurements must be chosen ac-
cording to the system consumption, as well as the cable
routes and distances, the chosen protective systems, and
the specific standards for fixed electrical systems in force in
the country where the hot tub is installed.
- The rated power supply voltage of the equipment is always
220-240V.
Spa-pack and balance tank
(the following considerations are also valid for the spa-pack "boost-
er kit"; refer also to the relative documentation).
- The Spa-pack must be installed in a ventilated indoor area,
which is only accessible to those with a key or tools, and it must
be protected from water and bad weather.
N.B. Since certain settings and general maintenance operations re-
quire access to devices present on the Spa-pack (heating tempera-
ture setting, filter backwash, emptying the system, etc.), it is advis-
able to ensure easy access to the systems control.
- The balance tank (to be installed as close as possible to the Hot
tub,
6) must be closed so that the electrical devices on it are
not accessible to the user without a key or tools.
with
exchanger
mm
2
- Ways of limiting access (for both the Spa-pack and the balance
2,5
tank) to unauthorized persons must take into account electrical
1,5
protection (direct and indirect contact) and the characteristics
of the materials used; in particular, any filler panels or structural
parts, if made of conductive material, must guarantee connec-
tion to the protection circuit (earth) and any supplementary
equipotential connection, if required by the type of installation.
22
without
heating system
heater (3 kW)
Hertz
mm
2
4
2,5
Jacuzzi Europe S.p.A. © 2023
with
with
exchanger
mm
2
mm
2
4
4
2,5
2,5