15 | Alarms and error messages
15
Alarms and error messages
15.1 List of alarms and errors
Alarms are displayed on the control panel in yellow. When an alarm is displayed the pellet stove can
continue to be used. Errors are displayed in red. When errors are displayed the pellet stove is not
ready for operation.
Warning code
Error code
Alarm - A001
Alarm - A002
Alarm - A003
Alarm - A004
Error - E001
Error - E004
Error - E101
Error - E102
Error – E107
Error - E108
Error - E109
Error - E110
Error - E113
Error - E114
Error - E115
50
Description
Fuel level low
Service due
Flue gas temperature
Low battery
IR communication error
Communication error
Ignition failed
Vacuum too low or too high
Firebox sensor
Safety switch I01 error
Safety switch I02 error
faulty room temperature sensor
Exhaust gas excess temperature
Firebox temperature too low
System shut-down
EN
Solution
Replenish pellets,
Set filling level to "FULL" again.
Maintenance by service technician required.
Exhaust gas temperature too high: service techni-
cian required.
Change control storage battery (CR2032).
The battery must be changed every 2 years as part
of a service.
Infra-red sensor malfunction,
contact service engineer.
Communication error between controls and dis-
play,
check data cable - plug connections.
Restart.
Possible causes:
1. The automatic start procedure has been manually
cancelled.
2. Supply air pipe, combustion pot, exhaust gas
pipes, exhaust gas fan or flue pipe contaminated.
3. Chimney draught contaminated.
4. Chimney draught too strong.
Firebox temperature sensor cable faulty. Call Ser-
vice.
RESET safety temperature limiter (STB)! Caution:
STB can only be reset after cooling down to below
105 °C.
1. Pellet hopper lid open.
2. Riddling grate not closed.
Room temperature sensor faulty.
Replace sensor.
Contact service engineer.
Exhaust extractor and flues are blocked.
Cleaning required.
Possible causes:
1. Ignition failed (empty combustion pot and restart
the appliance).
2. Fuel tank empty (fill up fuel tank).
Software must be reloaded. Contact service engin-
eer.