Operating manual Perry
1
Fig. 69: Taking out inspection blank
Fig. 70: Clean interior space
14.4 Changing the storage battery
A CR2032 battery is located in the control unit. This battery enables the control unit to save certain
data - e.g. time, date, heating times etc. even during a power failure, or when the mains power supply
is disconnected.
If the battery is flat, the control unit will continue to function normally. However, in the event of a power
failure, the above-mentioned data will be lost. These data must then be saved afresh.
Fig. 71: Changing the storage battery
2
3
EN
ü Take out inspection blank (1, 2, 3). To do so, please pro-
ceed as follows:
8) Undo nuts.
9) Take out inspection blank and gasket.
10) Clean interior space with a vacuum cleaner.
11) After cleaning, attach and install all parts again.
Change the battery every 2 years, as follows:
Changing the battery:
1) "ON" switch. Control systems must remain switched
on, as otherwise the data will be lost.
2) The battery is located on the central control unit. To
replace it, the right-hand side cladding of the pellet
stove must first be removed. Then remove the cover
of the control unit.
3) Use insulated pliers or a similar tool to remove the old
battery from the holder.
4) Insert the new battery, taking note of the correct po-
larity.
14 | Maintenance
49