5 | Technical data
5.2
General specifications
Technical data
Height [mm]
Width [mm]
Depth [mm]
Weight, basic appliance [kg]
Nominal heat efficiency [kW]
Partial load heat output [kW] (pellet)
Space heating capacity, at least (depending on the building insulation) [m³]
Maximum room-heating capacity (depending on the building insulation) [m³]
Efficiency [%]
At nominal heat efficiency
CO [mg/Nm³] at partial power
Flue gas temperature at nominal heat output [°C]
Partial output flue gas temperature [°C]
Flue gas mass flow [g/s]
Flue gas mass flow [g/s] for partial load
Minimum feed pressure at nominal heat output [Pa]
Minimum feed pressure for partial load [Pa]
Pellet hopper capacity [kg]
Pellet hopper capacity [l]
Fuel throughput, minimum [kg/h]
Fuel throughput, maximum [kg/h]
External air connection [Ø]
Flue pipe outlet, diameter [mm]
Power connection [V/Hz]
Temperature limits
Relative humidity
Electrical power consumption when switching on [W]
Electrical power consumption during operation [W]
Fire safety – distance from combustible materials, ceiling [mm]
Minimum distance from non-flammable materials [mm]
Safety distance to combustible materials, front [mm]
Safety distance to combustible materials, side [mm]
Safety distance to combustible materials, back [mm]
18
EN
Operating manual Perry
1121
535
525
209
7.5
2
82
245
89
6
198
176
97
5.3
3.7
10.8
8.2
25
39
0.5
1.7
80
80
230/50
0-40
non-condensing
325
approx. 12
-
50
500
200
200