Operating instructions
Intended use
This appliance has been designed for installation in natural gas
operated vehicles. It is not approved for installation in boats.
Other applications are also possible following consultation
with Truma.
Always observe the opera ting instructions and "Impor-
tant operating notes" prior to starting! The vehicle owner
is responsible for the correct operation of the appliance!
The installer or vehicle owner must apply the yellow sticker
with the warning information, which is enclosed with the ap-
pliance, to a place in the vehicle where it is clearly visible to all
users! Ask Truma to send you stickers, if necessary.
Control panel with sliding switch
b
a = Slide valve
Heating – Off – Ventilation
b = Slide valve for
high setting (large flame symbol)
low setting (small flame symbol)
Control panel with rotary switch
c = "Heating" rotary switch
high setting (large flame symbol)
low setting (small flame symbol)
d = "Off" rotary switch
e = "Ventilation" rotary switch
high setting (large symbol)
low setting (small symbol)
Switching on the Heating
– Remove cowl cap.
– Open gas extraction valve.
– Open quick-acting valve in the gas supply line.
– Adjust desired room temperature at rotary knob.
– Switching the heating on:
Control panel with sliding switch
Set the switch (a) to Heating and switch (b) to the desired
output setting.
Control panel with rotary switch
Set the rotary switch to the desired output setting (c).
If the outside temperature is low, switch to high setting.
The Trumatic E heater has been tested and approved for
operation, also when the vehicle is moving. The burner
with fan assistance guarantees satisfactory operation, even
under extremely windy conditions. National restrictions for
the operation of gas equipment while driving may need to be
taken into consideration.
14
a
Trumatic E
e
d
c
Switching on the Ventilation
Control panel with sliding switch:
Set switch (a) to Ventilation and switch (b) to the desired
output setting.
Control panel with rotary switch:
Set the rotary switch to the desired output setting (e).
Switching off
Set the sliding switch (a) or the rotary switch (d) to the centre.
If the appliance is switched off after a heating phase, the fan
can continue running in order to make use of the residual
heat.
If the device is not used for a long period, put on cowl cover
and close quick-acting valve in the gas supply line.
Green LED "Operating"
(under rotary control knob)
When the device is switched on (heating or ventilation), the
green LED must light up (the fan is operational). If the LED
does not shine, check the (main) switch. For this purpose ob-
serve respective instructions of the vehicle manufacturer.
During the heating process whilst the flame is burning, the
green LED shines twice as brightly. This also makes it possible
to determine the instantaneous switching point of the room
temperature.
Fuses
The device and control panel fuses are on the electronic
control unit on the device.
Device fuse (F1): 3.15 AT – slow – (EN 60127-2-3)
Control panel fuse (F3): 1.6 AT – slow –
The fine-wire fuse must only be replaced by a fuse of the
same design.
Red LED "Failure"
In the event of a failure, the red LED shines. Possible causes
for the failure can be e.g. no gas, insufficient combustion air,
heavily soiled rotor, defective fuse etc.. Deactivate by switch-
ing off and then switching on again.
Opening a window to which a window switch is fitted
and closing it again is the equivalent of switching off / on
at the control panel (e.g. a fault reset)!
Flash operation indicates that the operating voltage is too
low or too high for the appliance (charge battery, if necessary).
In Germany, always notify the Truma Service Centre if prob-
lems are encountered; in other countries the relevant service
partners should be contacted (see Truma Service Booklet or
www.truma.com).