18.4.3

Braking step


Press the
key repeatedly until the parameter
inversely.

Set the desired step by means of the control knob
B-braking steps can only be set for special rotors.
18.4.4

Run-down time

If a brake de-energisation speed has been set, it is not possible to set a run-down time.

Press the
key repeatedly until the parameter

Set the desired value by means of the control knob
18.4.5

Brake de-energisation speed


Press the
key repeatedly until the parameter n

Set the desired value by means of the control knob
18.5

Radius/Temperature

18.5.1

Radius


Press the
key repeatedly until the parameter r/mm is displayed and the input field is shown inversely.

Set the desired value by means of the control knob
The value of the RCF/RZB adapts automatically when the radius is changed; this is shown by the indication flashing.
18.5.2

Temperature


Press the
key repeatedly until the parameter T/°C is displayed and the input field is shown inversely.

Set the desired value by means of the control knob
18.6

Automatic buffer

The buffer comprises the program locations "----" and 90 to 99. Every time a centrifugation run is started, modified
centrifugation data are automatically stored in program location "----". The modified centrifugation data for the last 11
centrifugation runs are stored in the buffer and can be called up (see Chapter "Calling up programs").
19

Programming

19.1

Entering / modifying programs


Set the desired parameters (see Chapter "Entering centrifugation parameters").

Press the
key in order to select the parameter PROG-Nr. The input field will be displayed inversely.
PROG

Set the desired program location by means of the control knob
If the program location indicator flashes, then this program location has already had centrifugation data assigned
to it. In this case, set a free program location or overwrite the centrifugation data by continuing.

Press the
key once to save the settings in the desired program location.
STO
Press the
key twice to overwrite centrifugation data already stored.
STO
19.2

Calling up programs


Press the
key in order to select the parameter PROG-Nr. The input field will be displayed inversely.
PROG

Set the desired program location by means of the control knob

Press the
key. The centrifugation data for the selected program location will be displayed.
RCL
64/165
or
is displayed. The input field will be displayed
t
0-9
.
is displayed. The input field will be displayed inversely.
t
min:sec
.
(•)
/RPM is displayed. The input field will be displayed inversely.
.
.
.
.
.