Meldungen beim Auftreten eines Fehlers
Unexpected port assembly. Change device name to
%s.
Unknown SFP module on <Portnummer> (vendor:
\"%$str\").
SFP module on <Portnummer> is not supported
and remains deactivated.
Signaling contact controlled by user configuration. Signaling contact controlled by error state.
Local loop detected on <Portnummer>. Port disab‐
led.
Local loop detected on <Portnummer>. Port disab‐
led for <Anzahl> seconds.
Remote loop detected on <Portnummer>. Port di‐
sabled.
Remote loop detected on <Portnummer>. Port di‐
sabled for <Anzahl> seconds.
Local loop detected on <Portnummer>.
Remote loop detected on <Portnummer>.
Standby <partner | observer> conflicts with <active
| passive> state.
Standby <partner | observer> conflicts with obser‐
ver <on | off> configuration.
Standby <partner | observer> conflicts with <mas‐
ter | slave> role.
Standby slave: At least one port has no link.
FMP-Port <Portnummer>: Maintenance required,
Rx-Power: <empfangene Leistung> [dBm], Power
Loss: <Verlustleistung> [dB]
FMP-Port <Portnummer>: Maintenance deman‐
ded, Rx-Power: <empfangene Leistung> [dBm],
Power Loss: <Verlustleistung> [dB]
POF-Port <Portnummer>: Maintenance required,
Rx-Power: <empfangene Leistung> [dBm], Power
Margin: <Leistungsreserve> [dB]
POF-Port <Portnummer>: Maintenance deman‐
ded, Rx-Power: <empfangene Leistung> [dBm],
Power Margin: <Leistungsreserve> [dB]
Link Check: Broken link on <Portnummer> indica‐
ted by <Fehlerbeschreibung>. Port disabled.
Link Check: Multiple partners detected on <Port‐
nummer>.
Link Check: Unapproved configuration. Disable
Link Check on <Portnummer>.
SCALANCE X-300 / X-400
Projektierungshandbuch, 03/2022, C79000-G8900-C187-33
D.1 Fehlermeldungen des SCALANCE X300 / X400
Meldungen nach der Behebung eines Fehlers
Port assembly known.
Unknown SFP module on <Portnummer> removed.
Not supported SFP module on <Portnummer> re‐
moved.
<Portnummer> is enabled again after being disab‐
led by loop detecion.
<Portnummer> is enabled again after being disab‐
led by loop detecion.
<Portnummer> is enabled again after being disab‐
led by loop detecion.
<Portnummer> is enabled again after being disab‐
led by loop detecion.
<Portnummer> is enabled again for loop detecion.
<Portnummer> is enabled again for loop detecion.
Standby <partner | observer>'s state conflict resol‐
ved.
Standby <partner | observer>'s observer configura‐
tion conflict resolved.
Standby <partner | observer>'s role conflict resol‐
ved.
Standby slave: All ports linked up.
FMP-Port <Portnummer>: OK
FMP-Port <Portnummer>: OK
POF-Port <Portnummer>: OK
POF-Port <Portnummer>: OK
Link Check: Link on <Portnummer> OK. Port enab‐
led.
Link Check: Partner detection reset on <Portnum‐
mer>.
Link Check: Unapproved configuration resolved on
<Portnummer>.