Siemens SIMATIC NET SCALANCE X-400 Projektierungshandbuch Seite 404

Industrial ethernet switches
Inhaltsverzeichnis

Werbung

Anhang D
D.1 Fehlermeldungen des SCALANCE X300 / X400
Meldungen beim Auftreten eines Fehlers
Observer stopped recovering because of to many
(<Fehlerzahl>) repeated errors.
(Observer needs to be restarted (WBM/CLI) manual‐
ly).
Power down on line <ID der Spannungsversor‐
gung>.
Internal error: <Spannung> V power down.
Wrong module <Modulname> on slot <Slotnum‐
mer> (ID: <Modul-ID>).
C-PLUG not accepted. See System C-PLUG mask for
details.
C-PLUG interface unmounted. Restart required.
C-PLUG missing.
Media module for ring <Portnummer> missing.
DIP switch <Name des Schalters> changed. Restart
required.
DIP switch <Name des Schalters> differs from C-
PLUG. Restart required.
Internal error(s) and/or exception(s) occurred.
Device boot up incomplete.
RM <MAC-Adresse> lost.
Media module for standby <Portnummer> missing. Media module for standby <Portnummer> detec‐
PNIO fault - please use STEP 7 for diagnostics.
PNIO connection established.
Severe module change detected. Restart required. Severe module change reverted.
DIP switch settings manipulated ...
→ Redundancy will be started after next restart.
Authentication status on <Portnummer>: FAI‐
LED! Reason: %s.
Standby <observer | partner> freezes current state
<active | passive> because <master | slave> <MAC-
Adresse> gone.
Default route is stored in hardware.
Non-recoverable error on ring %u: RM receives test
frames from only one ring port.
Non-recoverable error on ring %u: Another redun‐
dancy manager detected.
Last MRP manager in ring %d won't stop on ring
ports <Portnummer> and <Portnummer> (danger
of network loops).
Redundancy mode transition not completed !\nis:
\"%s\", should: \"%s\".
Erroneous connected ring line on <Portnummer>
(should <Portnummer>).
Main power usage threshold exceeded.
404
Meldungen nach der Behebung eines Fehlers
Observer restarted because of user command.
Power up on line <ID der Spannungsversorgung>.
Internal error gone: <Spannung> V power is back.
Wrong module <Modulname> on slot <Slotnum‐
mer> removed.
C-PLUG accepted.
C-PLUG interface mounted.
C-PLUG detected.
Media module for ring <Portnummer> detected.
DIP switch <Name des Schalters> set back to origi‐
nal state.
DIP switch <Name des Schalters> set back to state
saved on C-PLUG.
Internal error(s) and/or exception(s) confirmed.
Device boot up complete.
RM <MAC-Adresse> detected.
ted.
PNIO fault - gone.
PNIO connection terminated.
DIP switch settings reset ...
→ Redundancy mode will not change after next
restart.
Authentication status on <Portnummer>: OK. Rea‐
son: %s.
Unfreeze standby state <active | passive> because
partner <MAC-Adresse> became visible.
Default route no longer in hardware.
Non-recoverable error gone on ring %u: RM recei‐
ves test frames from both ring ports.
Non-recoverable error gone on ring %u: Other re‐
dundancy manager gone.
MRP ring %d manager may stop now (no danger of
network loops anymore).
Redundancy mode transition to \"%s\" completed.
Erroneous connected ring line removed on <Port‐
nummer>.
Main power usage below threshold again.