Attach the service specification plate.
✓ Read off the serial number and manufac-
turing date from the original specification
plate and write it on the service
specification plate with a white,
waterproof pen.
22
Carry out the earthing test and high-voltage
test.
23
Perform a function test.
Result
✓ The housing has been replaced.
42
Replacing the heating plate
Prerequisite
– The appliance is disconnected from the mains.
– A new heating plate is available.
– A service specification plate is available.
– Torx® screwdrivers T10 and T15 are available.
– A flathead screwdriver no. 2 is available.
– A hexagon key size 5 is available.
– A pair of long-nose pliers is available.
– An ESD wristband is worn and correctly earthed.
WARNING
Danger of death from electric shock
Touching exposed current-carrying parts
can lead to severe injuries or death.
▶ Interrupt the power supply before
working on electrical components.
1
Remove the specification plate.
2
Loosen the screws (Torx® profile T15) on
the housing and remove the housing half.
3
Loosen the screws (Torx® profile T10) on
the printed circuit assembly.