The earthing cable must not be clamped
under the control electronics. Ensure that
the cable routing is neat.
16
Put on the printed circuit assembly and
tighten the screws (Torx® profile T10).
17
Insert the light pipe with the flat side facing
upwards.
18
Close the housing and screw it on (Torx®
profile T15).
✓ Observe the sequence when tightening
the screws.
✓ Note the torque (3.5 Nm).
10417165195 © 12-2022
971.328.00.0(00)
19
Attach the service specification plate.
✓ Read off the serial number and manufac-
turing date from the original specification
plate and write it on the service
specification plate with a white,
waterproof pen.
20
Carry out the earthing test and high-voltage
test.
21
Perform a function test.
Result
✓ The heating plate has been replaced.