8
Loosen the screw (hexagon key size 5) and
remove the earthing.
9
Loosen the screw (Torx® profile T20) and
remove the earthing.
10
Insert the new mains cable.
11
Connect the earthing (hexagon key size 5,
long-nose pliers).
✓ Note the sequence: serrated lock
washer, terminal lug, washer.
✓ Note the alignment of the terminal lug.
12
Connect earthing (Torx® profile T20).
✓ Note the sequence: serrated lock
washer, terminal lug.
10417165195 © 12-2022
971.328.00.0(00)
13
Fit strain relief and tighten the screws
(Torx® profile T10).
14
Press the clamps together for the mains
cable (long-nose pliers).
15
Connect the mains cable to the printed
circuit assembly (long-nose pliers).
The earthing cable must not be clamped
under the control electronics. Ensure that
the cable routing is neat.
16
Put on the printed circuit assembly and
tighten the screws (Torx® profile T10).