16
Press the terminals together (long-nose
pliers) and connect the cable to the printed
circuit assembly (long-nose pliers).
17
Insert the sensor cable.
10417165195 © 12-2022
971.328.00.0(00)
The earthing cable must not be clamped
under the control electronics. Ensure that
the cable routing is neat.
18
Put on the printed circuit assembly and
tighten the screws (Torx® profile T10).
19
Insert the light pipe with the flat side facing
upwards.
20
Close the housing and screw it on (Torx®
profile T15).
✓ Observe the sequence when tightening
the screws.
✓ Note the torque (3.5 Nm).