EN
Replacing the battery
Prerequisite
–
Urinal ceramic appliance has been
demounted.
–
Refer to illustration sequence
page 61 while carrying out the
instructions.
1
Disconnect both cables and detach
the control unit.
2
Remove and dispose of the dead
battery.
3
Insert a new battery.
4
Attach the control unit and connect
both cables.
Cleaning the basket filter
Prerequisite
–
Urinal ceramic appliance has been
demounted.
–
Refer to illustration sequence
page 62 while carrying out the
instructions.
1
Close the angle stop valve.
2
Loosen the reinforced braided hose
and remove the basket filter and
seal.
✓ Store the seal.
3
Clean the basket filter.
4
Insert the basket filter and seal.
Screw on the reinforced braided
hose.
5
Open the angle stop valve.
24
Cleaning the flow limiter
Prerequisite
–
Urinal ceramic appliance has been
demounted.
2
,
–
Refer to illustration sequence
page 64 while carrying out the
instructions.
1
2
3
4
5
6
7
8
3
,
Close the water supply valve.
Detach the control unit.
Demount the solenoid valve.
Remove and clean the flow limiter.
Insert the flow limiter.
Mount the solenoid valve.
Insert the control unit.
Open the water supply valve.
18014402741989259-1 © 07-2019
4
,
968.645.00.0(01)