Replacing insulation

Prerequisite
– The appliance is disconnected from the mains.
– A new insulation set is available.
– A service specification plate is available.
– Torx® screwdrivers T10 and T15 are available.
– A flathead screwdriver no. 2 is available.
– A hexagon key size 5 is available.
– A pair of long-nose pliers is available.
– An ESD wristband is worn and correctly earthed.
WARNING
Danger of death from electric shock
Touching exposed current-carrying parts
can lead to severe injuries or death.
▶ Interrupt the power supply before
working on electrical components.
1
Remove the specification plate.
2
Loosen the screws (Torx® profile T15) on
the housing and remove the housing half.
48
3
Loosen the screws (Torx® profile T10) on
the printed circuit assembly.
4
Open the terminals (mains cable, heating
plate) on the printed circuit assembly
(flathead screwdriver no. 2).
5
Remove the cable from the clamps (long-
nose pliers).
6
Disconnect the sensor cable.
7
Remove the printed circuit assembly.