18
Close the housing and screw it on (Torx®
profile T15).
✓ Observe the sequence when tightening
the screws.
✓ Note the torque (3.5 Nm).
19
Attach the service specification plate.
✓ Read off the serial number and manufac-
turing date from the original specification
plate and write it on the service
specification plate with a white,
waterproof pen.
20
Carry out the earthing test and high-voltage
test.
21
Perform a function test.
Result
✓ The insulation has been replaced.
10417165195 © 12-2022
971.328.00.0(00)