EN
12
Fasten the new heating plate (hexagon key
size 5).
✓ Note the sequence: serrated lock
washer, washer, insulating element.
13
Connect the earthing (hexagon key size 5,
long-nose pliers).
✓ Note the sequence: serrated lock
washer, terminal lug, washer.
✓ Note the alignment of the terminal lug.
44
14
Press the terminals together (long-nose
pliers) and connect the cable to the printed
circuit assembly (long-nose pliers).
15
Insert the sensor cable.
10417165195 © 12-2022