WE2110
27
Source for automatic output can be selected.
28
Custom Auto format. See the description of commands for more information about au-
tomatic output formats.
29
Allows the output string START character to be defined (normally 02).
30
Allows the output string first END character to be defined (normally 03).
31
Allows the output string second END character to be defined (00 = none).
32
Type of printer output can be set. Print outs can be done in single line, double line, to-
tal, or printed ticket. "A" or Automatic printing is identical to manual printing, but occurs
on stable weight.
33
A custom printer header can be set up for up to 2 lines of 20 characters. Each charac-
ter is displayed as L.CH.CCC where L = line number (1-2), CH = character number (01
to 20) and CCC is the character code (in decimal ASCII).
34
A custom format for the printout can be entered. Max. 50 characters are allowed. For-
mat NNN.CCC, where NNN = number of the character, CCC = ASCII code. For more
information refer to the description of commands.
35
Positioning of the printout. First parameter for the horizontal position, second parame-
ter for the vertical position.
36
The baud rate controls both serial 1 and serial 2 outputs. Different baud rates for each
interface are not possible
37
Controls the data flow. Each character set as shown on the table below.
N, O, E
parity is set for none, Odd or Even
8, 7
The number of data bits
1, 2
The number of stop bits
t, −
enable or disable RS485 termination resistors, on (+) or off (−)
2, 4
2 = RS232; 4 = RS485
d, −
enable or disable DTR handshake for printer
38
The Safety pass-code controls access to the SAVE Setup using the "Select Change"
key.
(If "000000" is set, no password is needed).
39
The Full pass-code controls access to the FULL Setup (hidden screw) using the SE-
TUP key and controls settings through the interface. "000000" means no protection.
Individual keys can be enabled (Y), disabled (N) or set for instant operation (I) without
40
a delay for No Motion.
41
Input function are selected. Card ZS provides 4 inputs, card ZCC one.
0 = ZERO Key
P = PRINT Key
S = Show Total
1 = Single Transmit to
Serial 1
42
The speed of the A/D converter can be set to synchronize with the primary frequency
of scale vibration for extremely high noise rejection. As a standard the mains fre-
quency is convenient.
Warning − this setting effects calibration of the WE2110!
43
Allows the special mV/V display test mode to be selected for scale base testing for 5
seconds.
A2181-1.0 de/en
t =
TARE Key
b =
Blank Display
C = Clear Total
2 =
Single Transmit to
Serial 2
G = GROSS Key
L =
Lock WE2110
U = Undo addition
H = Hold Display
E = Peak
F =
Live animal display