58
44
Allows the special high resolution (x10) display mode to be selected for scale base te-
sting.
45
Allows the outputs to be forced ON one at a time.
46
Shows a test display for the remote inputs with O = off and 1,2,3,4 = on.
47
Shows the numer of overloads (>130%) of the scale. In safe setup the counter can be
set to zero.
48
Allows individual setpoints to be enabled. Card ZS provides 4 outputs, card ZCC two.
A = Active Limit Switch
E = Error Indication
N = Net Indication
49
Stops the operator changing the Limit Switches using the (TARE) button long press.
50
Limit Switches can be set to trigger from Gross or Net weights.
51
Sets the Residual flow and hysteresis for tripping on Increasing or Decreasing weight
for Limit Switches.
52
Sets the sense of the output drivers for positive or negative logic
53
Setpoint alarm sounds may be set to OFF, Single, Dual, Continuous or display flashing
(f) is set.
54
The TARGET for output 1..4 can be entered in displayed weight units.
55
The HYSTERESIS for output 1..4 can be entered in displayed weight units
56
The (optional) RESIDUAL FLOW for output 1..4 can be entered in displayed weight
units.
57
Source for analogue output.
58
Select VOLT for −10 ... 10 V output, CUR for 4 .:. 20 mA, ABS.CUR for absolute
4 ... 20 mA e.g. for loss in weight systems
59
Fine calibration of the low level − either 0 Volt or 4 mA
60
Fine calibration of the high level − either 10 Volt or 20 mA
61
Allows the analogue output card to be tested by forcing the output either low or high.
62
The time is set similar to a normal digital clock (using 24 hour format).
63
The date is set using European format.
64
Activate the QA-feature. From the entered date the WE2110 will ask for maintenance .
65
The date for maintenance.
66
This step will delete ALL digital setup (but not calibration !) and return the WE2110 to
the original factory defaults.
67
Factory setting only.
68