9 Special functions

8.6 Operating hours

Current runtime/operating hours of ventilation
levels and selected components.
Parameters
Humidity protection
ventilation level
Reduced ventilation
level
Nominal ventilation
level
Ventilation level Intens-
ive ventilation
Total ventilation
Heat register
Switching contact Basic
circuit board (main
board)
Brine circulation pump
(ZP 1)
Zone shutter (ZP1)
3-way air shutter
Supplementary heating
relay (ZP1)

8.7 EnOcean wireless

1. In the EnOcean wireless menu, select "3rd unit
list".
2. Once a unit is selected, the list of components
appears with detailed information about the
EnOcean wireless unit, such as EEP code, name
etc.
Parameters
List of components

8.8 Internet

IP configuration
IP address
Subnet mask
Gateway
DNS
air@home
36
Display
Operating hours of fans
in humidity protection
ventilation
Operating hours of fans
in reduced ventilation
Operating hours of fans
in nominal ventilation
Operating hours of fans
in intensive ventilation.
Total operating hours of
the two fans
Operating hours of heat
register
Operating hours of
switching contact
Operating hours of
brine circulation pump
Operating hours of
zone shutter
Operating hours of 3-
way air shutter
Operating hours of sup-
plementary heat re-
gister relay
Display
Values & status of indi-
vidual components.

8.9 Software version

Parameters: Control
Comfort control unit
Serial number
Details about software version in controller, any
comfort control unit which may be connected and
the serial number of the ventilation unit.
Example:
Control 1.3.2
Comfort control unit 1.3.4
Serial number M151895223XF34R5Z7ZZ
Status of main version = 1.3
Status of revision = 2 or 4

8.10 Fault messages

The last five active faults are displayed in the
"Faults" menu.
Fan supply air
Fan exhaust air
Communication main control panel (Comfort con-
trol unit)
Sensor T exhaust air
Sensor T air inlet unit
Sensor T outgoing air
Sensor T supply air
Sensor T room BUS
System memory
System bus
Additional circuit board 1
Additional circuit board 2
Bypass
Supply air temperature too cold
Exhaust air temperature too cold
Frost protection
Zone shutter
External pre-heating
Setpoint pressure constancy not reached
To remedy faults, contact the specialist
electrical installer responsible for operating
your unit.

8.11 Information

Notes provide information on current system
statuses.
9 Special functions

9.1 Auto Sensor operation

(demand-driven operation)
Activates the automatic operation, with sensor
control, so that hygienic, perfect ventilation is en-
sured. The ventilation control takes place based
on the humidity and/or CO2/VOC air quality val-
ues. The automatic mode is deactivated for a lim-